FSD Aurora DC Inverter 19 SEER – 220V/60Hz – 12000 BTU

Inverter split A/C, cooling only, R410a, remote control, seer 19 220V

SKU: FSD-12CRDN1-MP0W Category:

Description

Specification

The Indoor Unit

Model Name:
FSD-12CRDN1-MP0W
Power Supply, V/Ph/Hz:
208/230V,1Ph,60Hz
Cooling:
Capacity (range) — Btu/h:
12000
Input — W:
1037
Rated current — A:
4.5
EER — Btu/w:
11.8
SEER — Btu/w:
19
MINIMUM CIRCUIT AMPACITY — A:
11
MAX FUSE — A:
15
Compressor:
Model:
ASK89D29UEZD
Type:
ROTARY
Brand:
GMCC
Capacity — Btu/h:
2670
Input — W:
702
Rated current(RLA) — A:
4.95
Locked rotor Amp(LRA) — A:
/
Thermal protector:
/
Thermal protector position:
N/A
Capacitor — uF:
Refrigerant oil/oil charge — ml:
VG74/170
Indoor Fan Motor:
Model:
YKFG-20-4-10L
Input — W:
47.4
RLA — A:
0.218
LRA — A:
Winding Resistance — Ω:
0
Capacitor — uF:
1.5
Speed(Hi/Mi/Lo) — r/min:
≥1320
Indoor air flow (Hi/Mi/Lo) — m3/h:
410/330/350
Indoor air flow (Hi/Mi/Lo) — CFM:
241/194/206
Indoor noise level (Hi/Mi/Lo) — dB(A):
37.5/34.5/24.5
Indoor Unit:
Dimension(W*D*H) — mm
802x189x297
Packing (W*D*H) — mm
875x285x375
Net/Gross weight — Kg
8.2/10.8

The Outdoor Unit

Model Name:
FSD-11CFN1-MQ0W
Outdoor Fan Motor:
Model:
ZKFN-40-8-1L-5
Input — W:
40.0
RLA — A:
0.56
LRA — A:
0.7
Winding Resistance — Ω:
100
Capacitor — uF:
0
Speed — r/min:
850/700
Outdoor air flow — m3/h:
2091
Outdoor air flow — CFM:
1231
Outdoor noise level — dB(A):
51.5
Outdoor Unit:
Dimension(W*D*H) — mm
770x300x555
Packing (W*D*H) — mm
900x345x585
Net/Gross weight — Kg
24.8/27
Refrigerant type —oz:
R410A/0.53
Refrigerant precharge —ft:
25
Additional charge for each ft —oz:
0.161 6mm_0.322 9MM
Design pressure —PSIG:
550/340
Refrigerant Piping:
Liquid side/ Gas side —mm(inch):
6.35mm(1/4in)/12.7mm(1/2in)
Max. refrigerant pipe length — m:
25
Max. refrigerant pipe length — ft:
82
Max. difference in level — m:
10
Max. difference in level — ft:
33
Connection Wiring:
16AWG*4 Stranded, unshielded
Thermostat Type:
Remote Control
Room Temperature:
Indoor(cooling/ heating) — C:
17⁓32/ —
Outdoor(cooling/heating) — C:
0⁓50/ —
Application area (cooling standard) — m2:
15-22
Application area (cooling standard) — sq.ft:
161-237
Qty’per 20’ /40’ /40’HQ:
108/225/234