FSD Aurora DC Inverter 19 SEER – 220V/60Hz – 24000 BTU

Inverter split A/C, cooling only, R410a, remote control, seer 19 220V

SKU: FSD-22CRDN1-MP0W Category:

Description

Specification

The Indoor Unit

Model Name:
FSD-22CRDN1-MP0W
Power Supply, V/Ph/Hz:
208/230V,1Ph,60Hz
Cooling:
Capacity (range) — Btu/h:
24000
Input — W:
1960
Rated current — A:
9
EER — Btu/w:
10.9
SEER — Btu/w:
19
MINIMUM CIRCUIT AMPACITY — A:
18
MAX FUSE — A:
25
Compressor:
Model:
ATN150D30UFZA
Type:
ROTARY
Brand:
GMCC
Capacity — Btu/h:
4500
Input — W:
1160
Rated current(RLA) — A:
8
Locked rotor Amp(LRA) — A:
/
Thermal protector:
/
Thermal protector position:
N/A
Capacitor — uF:
Refrigerant oil/oil charge — ml:
VG74/450
Indoor Fan Motor:
Model:
YKFG-45-4-13
Input — W:
89
RLA — A:
0.45
LRA — A:
0.546
Winding Resistance — Ω:
125.2
Capacitor — uF:
3
Speed(Hi/Mi/Lo) — r/min:
1100/900/800
Indoor air flow (Hi/Mi/Lo) — m3/h:
988/776/562
Indoor air flow (Hi/Mi/Lo) — CFM:
582/457/331
Indoor noise level (Hi/Mi/Lo) — dB(A):
46/40.5/34.0
Indoor Unit:
Dimension(W*D*H) — mm
1080x226x335
Packing (W*D*H) — mm
1155x415x315
Net/Gross weight — Kg
14.3/17.9

The Outdoor Unit

Model Name:
FSD-22CFN1-MR0W
Outdoor Fan Motor:
Model:
ZKFN-50-8-2
Input — W:
115
RLA — A:
0.6
LRA — A:
0
Winding Resistance — Ω:
37.3
Capacitor — uF:
/
Speed — r/min:
800/550
Outdoor air flow — m3/h:
3100
Outdoor air flow — CFM:
1825
Outdoor noise level — dB(A):
57
Outdoor Unit:
Dimension(W*D*H) — mm
845x363x702
Packing (W*D*H) — mm
965x395x765
Net/Gross weight — Kg
40.2/43.5
Refrigerant type —oz:
R410A/40.9
Refrigerant precharge —ft:
25
Additional charge for each ft —oz:
0.161 6mm_0.322 9MM
Design pressure —PSIG:
550/340
Refrigerant Piping:
Liquid side/ Gas side —mm(inch):
6.35mm(1/4in)/15.9mm(5/8in)
Max. refrigerant pipe length — m:
30
Max. refrigerant pipe length — ft:
98
Max. difference in level — m:
20
Max. difference in level — ft:
66
Connection Wiring:
16AWG*4 Stranded, unshielded
Thermostat Type:
Remote Control
Room Temperature:
Indoor(cooling/ heating) — C:
17⁓32/ —
Outdoor(cooling/heating) — C:
-15⁓50/ —
Application area (cooling standard) — m2:
29-43
Application area (cooling standard) — sq.ft:
312-463
Qty’per 20’ /40’ /40’HQ:
60/126/142